Key to optical parameters: (all units in millimeters unless otherwise stated)
λ Wavelength of incident light in microns (>0.55 mm)
L1 Object distance (from object point to lens' front surface)
L2 Image distance (from lens' back surface to image point)
N0 On-axis refractive index of SELFOC® lens
√A Index gradient constant (mm-1)
Z Lens length
EFL Effective focal length (from rear primary plane to rear focal plane)
BFL Back focal length (from rear lens surface to rear focal plane)
MT Transverse magnification
θ+ Maximum angle from object above axis
θ- Maximum angle from object below axis
Hm Maximum object height
Ls Distance from lens surface to aperture stop
Steps for using the SELFOC® MICROLENS Tables:
- If the object distance for your application is known, click the sheet tab entitled "Obj. Distance". If the desired magnification is known, click the sheet tab entitled "Magnification".
- Enter the required data in the colored data cells. As you enter numeric values, the SELFOC® lens parameters such as N0, √A, and EFL will be recalculated in the lens table.
- Adjust the Pitch in small increments and observe how the optical parameters are altered. Recall that 2πP=Z√A.
|